60 Configuration Software and Utilities
61MAXDATA PLATINUM 90002R Server System
The About box contains an Advanced button that can be used to show version information for
components related to the SMU application. See the example below.
Figure 25. SMU Application About Box (Advanced button selected)
Server Discovery
The remote SMU application requires that the Intel
®
Server Management software be installed on
the client system. When the ISM software is run, it performs a discovery of all servers that support
tools available within ISM. The discovered servers are displayed in the ISM Console. By clicking on a
server name in the table, a list of tools supported on that server is displayed. The SMU is contained
in the set of tools listed under the heading “Reboot to Service Partition.
Remote SMU Application
The path used to connect to a target server is dened by the ISM software, based on information it
has about each server. After a LAN connection is established between the remote SMU application
and SMU core components on the server, the application and the core components set up a socket
connection to communicate through.
The sequence of steps that occur when starting the remote SMU application is listed below. These
steps occur under the control of the ISM software, not the SMU software, and all errors are handled
by the ISM software.
1. In the ISM Console software, click on Reboot to Service Partition under the list of tools for a
server shown.
2. Enter the username and password for an out-of-band connection on the Service Partition
Utilities screen.
3. Click Login.
4. When the server has been successfully rebooted to the service partition software, the
supported service partition utilities are displayed, as shown below. Click on System
Maintenance Utility to launch the SMU application. ISM passes connection information to
the SMU so the SMU can communicate with the target server. Up to this point, all errors are
handled by the ISM software, not the SMU.