Seitenansicht 20
20 System Description
21MAXDATA PLATINUM 90002R Server System
TP00304
A
Figure 9. AC Power Status LEDs
LED Description
AC1 (green) On - AC input #1 available.
Off - AC input #1 unavailable or below voltage threshold to power up the
system.
AC2 (green) On - AC input #2 available.
Off - AC input #2 unavailable or below voltage threshold to power up the
system.
ACR (green) On - redundant feature is available.
Off - redundant feature is not available
The power redundancy feature requires each of the following conditions be present.
AC input #1 available
AC input #2 available
Power good signals asserted from all three power supply modules
TS-OK signal is asserted